[1]赵芳芳,李 安.宽体探测器CT冠状动脉成像优化对比剂注射时间与不同管电压相关性研究[J].陕西医学杂志,2023,52(5):563-566.[doi:DOI:10.3969/j.issn.1000-7377.2023.05.015]
 ZHAO Fangfang,LI An.Correlation between contrast injection time and tube voltages for coronary imaging optimization with wide-detector CT[J].,2023,52(5):563-566.[doi:DOI:10.3969/j.issn.1000-7377.2023.05.015]
点击复制

宽体探测器CT冠状动脉成像优化对比剂注射时间与不同管电压相关性研究
分享到:

《陕西医学杂志》[ISSN:1000-7377/CN:61-1281/TN]

卷:
52
期数:
2023年5期
页码:
563-566
栏目:
临床研究
出版日期:
2023-05-05

文章信息/Info

Title:
Correlation between contrast injection time and tube voltages for coronary imaging optimization with wide-detector CT
作者:
赵芳芳12李 安1
(1.陕西省人民医院,陕西 西安 710068; 2.长安医院医学影像科,陕西 西安 710016)
Author(s):
ZHAO FangfangLI An
(Shaanxi Provincial People's Hospital,Xi'an 710068,China)
关键词:
Revolution CT 冠状动脉成像 管电压 对比剂 辐射剂量 图像质量
Keywords:
Revolution CT Coronary angiography Tube voltage Contrast agent Radiation dosage Image quality
分类号:
R 445.4
DOI:
DOI:10.3969/j.issn.1000-7377.2023.05.015
文献标志码:
A
摘要:
目的:探讨Revoluntion 宽体探测器CT冠状动脉成像优化对比剂注射时间与不同管电压的相关性。方法:收集拟诊冠心病并行Revolution CT冠状动脉成像(CCTA)受检者60例作为研究对象,随机分为两组。A组为对照组(30例),管电压为120 kV; B组为试验组(30例),管电压为100 kV。对比剂注入时间均为8 s,按照25 mgI/(kg·s)碘流率计算打药药量,迭代重组(ASIR-V)权重80%,联合冠脉冻结技术(SSF)重建图像。分别测量主动脉根部、右冠状动脉(RCA)、左前降支(LAD ),以及左回旋支(LCX)近段管腔和其周围脂肪组织CT值,计算血管信噪比(SNR)和对比噪声比(CNR)。记录CT容积剂量指数(CTDI)、长度乘积(DLP),并计算有效辐射剂量(ED); 由两名具有心血管影像高年资医师根据美国心脏协会(AHA)冠状动脉改良分段法(分16段)及远端分支运用5分法进行图像质量主观评价,应用Kappa检验判断观察者间一致性。比较两组间一般资料,图像质量主、客观评价指标及ED。结果:两组患者一般资料、造影剂用量、主观评分等比较差异均无统计学意义(均P>0.05); CTDI、DLP、ED比较差异均有统计学意义(均P<0.05); B组ED较A组下降约30%。两组间各节段血管内CT值比较B组较A组提升,差异有统计学意义(均P<0.05); 两组间SNR、CNR比较差异无统计学意义(均P>0.05)。结论:宽体探测器CT冠状动脉成像优化对比剂注射时间8 s,在低管电压100 kV图像质量优于高管电压120 kV,且可以有效降低辐射剂量。
Abstract:
Objective:To study the correlation between contrast injection time and tube voltages for coronary imaging optimization with wide-detectors.Methods:A totalt of 60 patients with suspected coronary heart disease who underwent CT coronary angiography(CCTA)were collected and divided into two groups.Group A(30 cases)was control group,and the tube voltage was 120 kV.Group B(30 cases)was the study group,and the tube voltage was 100 kV.Contrast agent injection time was 8 seconds.The contrast dosage was calculated according to the iodine flow rate of 25 mgI/(kg·s),and the 80% ASIR-V images were reconstructed with SSF.CT values of proximal aortic root,right coronary artery(RCA),left anterior descending artery(LAD),and left circumflex artery(LCX)lumens and their surrounding adipose tissue were measured to calculate vascular SNR and CNR.CTDI and DLP were recorded to calculate the effective dose(ED).Subjective imaging qualities were compared and interobserver agreement was evaluated with kappa values.The general data,subjective and objective evaluation indexes of image quality and ED were compared between the two groups.Results:There were no significant differences in patient demographics,contrast agent consumption and subjective scores between these two groups(P>0.05).There were significant differences in CTDI,DLP and ED(all P<0.05).ED of Group B decreased by 30% compared with group A.The intravascular CT values were increased in group B compared with group A(all P<0.05).There were no significant differences in SNR and CNR between the two groups(all P>0.05).Conclusion:The image quality at low tube voltage 100 kV with optimized contrast agent injection time of 8 s is superior to the high tube voltage 120 kV,and can reduce radiation dose effectively.

参考文献/References:

[1] 尹小花,徐 荣,郭 鑫,等.冠状动脉CT血管造影预测冠脉斑块患者发生左心室重构临床价值研究[J].陕西医学杂志,2021,50(2):192-196,200.
[2] 马党捐,康彦智,柴茂林.64排128层螺旋CT冠状动脉成像在冠心病患者诊断中的价值研究[J].陕西医学杂志,2019,48(5):624-627.
[3] Liu Z,Sun Y,Zhang Z,et al.Feasibility of free-breathing CCTA using 256-MDCT[J].Medicine(Baltimore),2016,95(27):4096.
[4] Nie P,Yang G,Wang X,et al.Application of prospective ECG-gated high-pitch 128-slice dual-source CT angiography in the diagnosis of congenital extracardiac vascular anomalies in infants and children[J].PLoS One,2014,9(12):115793.
[5] 易 妍,曹 剑,林 路,等.第3代双源CT 70 kV大螺距扫描冠状动脉CT血管成像在不同体质量指数患者中的应用[J].中国医学科学院学报,2017,39(1):42-48.
[6] Matveeva A,Schmitt RR,Edtinger K,et al.Coronary CT angiography in patients with atrial fibrillation:Standard-dose and low-dose imaging with a high-resolution whole-heart CT scanner[J].Eur Radiol,2018,28(8):3432-3440.
[7] Hong C,Becker CR,Huber A,et al.ECG-gated reconstructed multi-detector row CT coronary angiography:Effect of varying trigger delay on image quality[J].Radiology,2001,220(3):712-717.
[8] 袁龙宾.256层螺旋CT冠脉成像诊断冠脉疾病临床价值研究[D].长春:吉林大学,2020.
[9] 樊 刚,李 波,董 莉,等.血管内超声与64排螺旋CT冠状动脉CTA对冠脉钙化病变定性、定量检测价值比较[J].中国CT和MRI杂志,2021,19(1):90-92.
[10] Gill GS,Araujo GP,Garcia-Garcia HM.Is negative coronary CT angiogram a no cardiovascular event warranty over 10 years?[J].JACC Cardiovasc Imaging,2019,12(2):382-383.
[11] 崔 磊,王璐璐,李先进,等.肥厚型心肌病合并心尖部室壁瘤及室性心动过速1例[J].中华心血管病杂志,2021,49(3):276-277.
[12] 张龙江,唐春香,卢光明.积极推动前沿心血管CT技术的临床应用[J].中华医学杂志,2021,101(39):3187-3189.
[13] 赵晓静,张 苗,卢 洁.Revolution CT冠状动脉成像技术的应用及研究进展[J].中国医疗设备,2022,37(6):158-161.
[14] Andreini D,Pontone G,Mushtaq S,et al.Image quality and radiation dose of coronary CT angiography performed with whole-heart coverage CT scanner with intra-cycle motion correction algorithm in patients with atrial fibrillation[J].Eur Radiol,2018,28:1383-1392.
[15] 中华医学会放射学分会质量控制与安全管理专业委员会.心血管CT成像辐射剂量优化中国专家共识[J].中华医学杂志,2016,96(7):510-516.
[16] 吕 蓉,韩宇欣,孙俊杰,等.图像CT值与管电流、管电压及碘浓度的关系及降低管电压时对比剂的合理用量[J].中华放射学杂志,2017,35(6):456-459.
[17] Bae KT.Intravenous contrast medium administration and scan timing at CT:Considerations and approaches[J].Radiology,2010,256(1):32-61.
[18] 王春辉,张永海.RevolutionCT对冠脉CTA图像质量的影响因素研究[J].影像研究与医学应用,2020,4(3):3-5.
[19] Pomposelli F.Arterial imaging in patients with lower extremity ischemia and diabetes mellitus[J].Journal of Vascular Surgery,2010,52(3):81-91.
[20] 李 艳.正常体质量指数患者Revolution CT双低冠状动脉成像的可行性研究[D].苏州:苏州大学,2016.
[21] 陈依林,刘元芬.70 kV与智能最佳管电压的冠状动脉血管成像在宽体探测器上的对比研究[J].中国卫生标准管理,2018,9(23):106-109.
[22] 陈玉环,胡智军,刘振堂,等.宽体探测器低管电压(70 kV)结合迭代重组(ASIR-V)算法在双低剂量CT冠状动脉成像中的应用[J].影像诊断与介入放射学,2019,32(1):32-38.
[23] 李爱华,陈 超,王 琦,等.优化对比剂注射时间在256排螺旋CT冠状动脉血管成像中的应用价值[J].中国CT和MRI杂志,2019,17(1):67-70.